Sign In | Join Free | My webtextiles.com |
|
Categories | Energy Meter Testing Equipment |
---|---|
Brand Name: | GENY |
Model Number: | YC1893D |
Certification: | ISO, CE |
Place of Origin: | CHINA |
MOQ: | 1 pcs |
Price: | negotiation |
Payment Terms: | L/C,T/T,D/P |
Supply Ability: | 30 PCS per month |
Delivery Time: | 30 days after order confirmed |
Packaging Details: | Plywood case |
Accuracy class: | Class 0.02/0.05 |
Test voltage output: | 3* (24V~288V)(or customized) |
Test current output: | 3* (1mA - 100A) |
Frequency Range: | 45Hz~65Hz |
Company Info. |
Guangzhou GENY Electric Co., Ltd |
Verified Supplier |
View Contact Details |
Product List |
GENY meter test systems leverage state-of-the-art electronic metrology and a modular architecture, integrating precision reference standards with high-stability power amplifiers to meet the exacting demands of energy-meter manufacturers, power utilities, metrology laboratories, inspection authorities, and industrial test facilities.
The YC1893D meter test system is a full-automatic test system for testing and calibration of both single-phase and three-phase electric energy meters, which composes of:
The YC1893D meter test system is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:
Technical spec. | |
Number of meter positions | 24 |
Accuracy | 0.05 / 0.02 |
Power Source | YCS-103-1200 |
Standard Meter | SZ03A-K6 / SZ03A-K8 / Radian RD-33 |
Scanning Head | YCG-S Series |
Voltage | |
Test voltage output(Phase-Neutral) | 3* (24V~288V)(or customized) |
Power of the voltage output | Max. 3x500VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Current | |
Test current output | 3* (1mA - 100A) |
Power of the current output | Max. 3x750VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Phase angle | |
Range | 0~360⁰ |
Resolution | 0.01⁰ |
Setting accuracy | 0.1⁰ |
Frequency | |
Range | 45Hz~65Hz |
Resolution | 0.01Hz |
Error display | |
Type of error display | Red LED |
Resolution of error displays | 8 digitals |
Other | |
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature | -10°C~+40°C |
Relative humidity | 35%~85% |
![]() |