Sign In | Join Free | My webtextiles.com |
|
Categories | Elevator load weighting device |
---|---|
Place of Origin: | China for elevator load weighting device |
Brand Name: | ECW |
Certification: | ISO9001 for elevator parts |
Model Number: | EWC-XZ3 |
Applicable: | for 2:1 roping traction elevator with the detection rang ≤500-7000kg |
Sensor: | Direct connection:type ECW-GA |
Landing compensation: | 3 ways of self-adapting:Fuzz,Double leveing,door -zone+direction |
Installing position: | sensor type ECW-GA On traction rope |
Install position: | controller:in control cabinet in machine-room |
Output: | 3 channel programmable:Light load,Full load, over load |
Analog: | no |
Power supply: | AC/DC 24V |
Type: | elevator parts |
key words: | elevator load sensor, load cell |
MOQ: | 1 SET (Including controller ECW-XZ3 and load sensor ECW-GB) |
Price: | USD 0-200/SET |
Packaging Details: | 1 SET/Small box |
Delivery Time: | 7-10 working days by DHL,EMS,Container ets |
Payment Terms: | TT, Paypal, Western Union |
Supply Ability: | 10000 piece /Month |
ECW XZ3Elevator Lifting Weighing Devices, Elevator Load Weighing Parts Elevator Spare Parts ECW XZ3Elevator Lifting Weighing Devices, Elevator Load Weighing Parts Elevator Spare Parts
One set including controller ECW-XZ3 and load sensor ECW-GB(Tension sensor)
Application Range Being applicable to all traction elevators with fixed car platform with the load of 500kg~3000kg
Landing Compensation Method Auto adapting intelligent fuzzy compensation
Sensitivity Elevator Rated Capacity/200 (Example: The rated capacity is 1000kg, and the
sensitivity is 5kg ) [This data may be affected by elevator mechanical performance.]
System Error ≤0.5% (5~40 centigrade )
Non-linearity ≤0.5%
Output Mode 1.2-channel programmable output modes are: No load, light load, semi full load, heavy load, rated
load, overload (customer may set the changing range freely).
2.Each channel can be programmed as dynamic Close or Open contact.
3.Contact Capacity: DC/AC 48V/100mA.
Analogue output :It performs linear change (0~10V) when Elevator load is changing
from “no load~rated load”.
Operation Ambient Temperature -20~55 centigrade centigrade
Relative Humidity Reaction 20%~90%RH
Reaction Time ≤0.3Second
Power Supply AC/DC24(±10%)V/200mA
Install Position Sensor Section:At the place of traction rope shackle
Controller Section:Control Cabinet in machineroom. See the attached
figure for installing dimensions.
Overall Size Sensor Section:See the figure;Controller Section:See the figure
M:The intension exceeding the limit parameters listed above may result in the abnormality or permanent damage to the system.
Main Characteristics:
![]() |