Sign In | Join Free | My webtextiles.com |
|
Categories | Vehicle Detector Sensor |
---|---|
Brand Name: | SINOMATIC |
Model Number: | PD-132 |
Certification: | CE/ ISO |
Place of Origin: | Shenzhen, China. |
MOQ: | Sample order accepted |
Price: | negotiable |
Payment Terms: | T/T, L/C, D/A, D/P, Western Union, MoneyGram |
Supply Ability: | 3,0000pcs per month |
Delivery Time: | 2-5 working days after payment received |
Packaging Details: | Carton/Plywood box/Pallet |
Reaction time: | 100ms |
Voltage available: | 230VAC , 115V AC, 24V DC/AC, 12VDC/AC |
Loop connection wiring: | Maximum length 200 meters Twisted at least 20 times per meter |
Operating temperature: | -20°C to +65°C |
sensitivity: | 4 levels |
Pacakge: | Carton |
Company Info. |
SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED |
Verified Supplier |
View Contact Details |
Product List |
CE Approved Parking Vehicle Access Control Loop Detector Model PD132
PRODUCT DESCRIPTION
Loop Detectors are used with vehicle detection loops to create an inductance from a magnetic field to sense
vehicular traffic and increase access control. Loop wire is buried underground beneath a road or driveway and
are connected to inductive loop vehicle detectors to detect the presence of a vehicle. They are most commonly
used under roadways to detect vehicles stopped at traffic lights.
Operating Guide
The detector must be installed in a convenient weatherproof
location as close to the loop as possible.
WARING:
1) This unit must be earthed.
2) Installation and operation by service professional only.
3) Disconnect power before working on this unit.
A correct loop configuration and detector installation will ensure
a successful inductive loop
detection system.
Technical parameters of Loop Detector
Main Features:
1) Reset Switch : The reset switch enables the detector to be manually reset during commissioning and testing.
This results in the detector re-tuning the sensing loop and
becoming ready for vehicle detection ;
2) Selectable Pulse Time : This feature sets the length of time
that the pulse relay will be energized for 1 Second
or 0.5 Seconds ;
3) Pulse Relay Selection : The Pulse Relay may be configured to
energize on detection of a vehicle or when the
vehicle leaves the loop ;
4) Sensitivity Boost : This feature sets the undetect level to
maximum sensitivity and is used to prevent loss of
detection of high-bed vehicles ;
5) Switch Selectable Sensibility : 4 sensitivity setting are
available on the switches to allow flexibility in configuration ;
6) Switch Selectable Frequency : 4 frequency settings are available
to prevent cross-talk between adjacent loops ;
7) Filter Option : This option is used to provide a delay between
detection of the vehicle and switchiing of the output
relay . This relay is normally used to prevent false detection of
small or fast moving objects ;
8) Permanent Presence Option : This feature ensure detection of the
vehicle will be maintained when the vehicle is
parked over the loop for extended periods .
![]() |