Sign In | Join Free | My webtextiles.com |
|
Categories | Generator Test Equipment |
---|---|
Brand Name: | Fanke High-Voltage |
Model Number: | FKGST 12KV |
Certification: | ISO9001 |
Place of Origin: | China |
MOQ: | One unit |
Price: | Negotiable |
Payment Terms: | T/T |
Supply Ability: | 10units/month |
Delivery Time: | 10 work days |
Packaging Details: | Export standard wooden case with fumigation free |
Usage: | Capacitance & Tan Delta Tester within 12KV or 12KV |
HV output: | 0-12KV |
Test object: | Motor , power generator and so on. |
Test range: | 50pF~1uF; 0~12KV |
Anti-interference: | Variable Frequency Method, 5mA |
Test Accuracy: | Reading*1.5% |
12KV Transformer Capacitance & Tan Delta Tester , Automatic Tan
Delta Tester , Generator Tan Delta Tester
I. Products Description
FKGST 12KV Tan Delta (dissipation factor) Tester consists of
variable frequency power, tan delta bridge, testing transformer and
standard capacitor inside the tester. Variable frequency power can
produce five kinds of frequency: 45Hz, 50Hz, 55Hz, 60Hz and 65Hz
under which test can be done. Variable frequency technique adopted
in this tester can ensure high accuracy in high interference
environment.
Model FKGST Automatic 12KV Capacitance &Dissipation Factor Test Set
is used to measure dissipation factor (PF) in heavy interference
site such as power plants or power substations. It can also be used
in laboratory for high accurate test. The meter is whole in one
designed: including precision digital bridge, power unit, reference
capacitor (CN), step-up transformer and other electronic circuits.
It’s also using frequency shift technology, FFT (Fast Fourier
Transform algorithm) and digital filtering. When started, it’s
running automatically and then outputs the results on LCD display
and prints the results automatically.
II. Test principle
Fig 1 Wiring Diagram of Main Power
RX1---Sampling resistance in ungrounded test specimen measurement
RX2---Sampling resistance in grounded test specimen measurement
CN---Standard capacitor
RN---Sampling resistance of reference signal
CVT---Voltage output terminal in CVT measurement by means of
self-excitation.
III. Technical Parameters
1. Input: 220V+5%, 50Hz, 1KVA
2. Output:voltage:0~12kV (0.5kV/step to raise voltage)
current:100mA continuous
Max. 200mA, 5min on/15min off (10kV)
Max.160mA, 5min on/15min off (12kV)
3.Test range:
3.1 voltage:0~12kV resolution:1V
3.2 capacitance: 10kV, 50pF~60000pF(50Hz)
12kV, 50pF~44000pF(50Hz)
0.5kV, 50pF~1uF(50Hz)
3.3 Max. resolution:0.01pF
3.4 Tan delta:0~10% Maximum resolution:0.00001
4.Accuracy:
4.1 voltage(RMS):+200V
4.2 capacitance:+(Reading*1.0%+1pF)
4.3 in ungrounded test specimen measurement +Reading*1.5%+1pF
4.4 in grounded test specimen measurement tan delta:+reading*1.0%+0.0005
5.Operational environment:
5.1operation temperature:-5℃~55℃
5.2 humidity:<85%
5.3 storage temperature:-20℃~55℃
III. Configuration:
SN | NAME | Qty |
1 | FKGST Automatic 12KV Capacitance &Dissipation Factor Tester | 1set |
2 | 10 meters Hipot measuring signal lines (red) | 1pec |
3 | 10 meters measuring signal lines (black) | 2pecs |
4 | 8 m CVT Low voltage output line | 1pec |
5 | Power line | 1pec |
6 | 8 m Earth line | 1pec |
7 | Spare printing paper | 1pec |
8 | 5A fuse | 1pec |
9 | Feltpad | 1pec |
10 | Manual | 1pec |
11 | certificate of inspection | 1pec |
12 | accessory case fro connection lines | 1pec |
![]() |