Brand Name: | Newscen |
Model Number: | COVID-19 IgG/IgM |
Certification: | ISO9001, CE, TUV, FDA |
Place of Origin: | China |
MOQ: | 10 Boxes or 400 Kits (40 Kits/Box) |
Price: | USD0.37/Cassette |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 50,000 Kits Per Day |
Delivery Time: | 8 days |
Packaging Details: | 40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm |
Methodology: | Colloidal Gold |
Shelf Life: | 2 Years |
OEM / ODM: | Available |
Result Time: | Read in 15 Minutes |
Manufacturer/Trader: | Manufacturer |
FDA: | Yes |
Company Info. |
Newscen Biopharm Co., Limited |
View Contact Details |
Product List |
Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette
Home Use SARS-CoV-2 Antibody IgG/IgM Colloidal Gold Screening Test
For IVD
Main Features
1. Fast to get the result in 15~20 mins.
2. High sensitivity and specificity.
3. Simple to use.
4. Certified by Authoritative Certification
5. High Accurate and Reliable
6. Ambient storage.
7. Unique 3-line Patented Design
8. Meet Multiple Criteria as follows:
EN ISO 13485:2016 EN 13612:2002
EN ISO 14971:2012 EN ISO 23640:2015
EN ISO 18113-1:2011 EN ISO 18113-2:2011
EN ISO 15223-1:2016 EN 13641:2002
Assay Procedure
Sample preparation: Fresh serum, plasma or whole blood samples, no
pretreatment is required. lf the samples are stored in2~8℃, the
samples should be restored at room temperature for15~30 minutes
before use, returned to room temperature, and thoroughly mixed
before testing.
Reagent preparation: Open the package, the pouch should be sealed
well. lf the test reagent stores in the refrigerator, it should be
restored to room temperature. Then open the package pouch and take
out the test reagent, place it on the platform.
Detection and interpretation: Add10µL serum/plasma or 20µL whole
blood sample into S well, after the sample has permeated
completely, add 2 drops diluent buffer. Read the result in15-20
minutes, interpret the test result after 20 minutes may cause false
result.
Interpretation of Results
Positive of lgG and IgM: One color line in the control zone(C), one
color line in the test zone(G) and one color line in the test
zone(M) .Indicates IgG and IgM test result is positive.
Positive of IgG: One color line in the control zone(C) and one
color line in the test zone(G), indicates lgG test result is
positive.
Positive of lgM: One color line in the control zone(C) and one
color line in the test zone(M), indicates IgM test result is
positive.
Negative of lgG and IgM: Only one color line in the control zone(C)
indicates IgG and IgM test result is negative.
Invalid: If no color line appears in the control zone(C), the test
is invalid.Discard the test cassette and perform with new cassette.
Built-In Control
COVID-19IgG/lgM Rapid Test Cassette has a built-in procedural control that demonstrates assay validity. A color line appeared on the control zone(C) indicates that the test runs correctly.
Materials Required But Not Provided
Timer or stopwatch
Blood collection devices, for the testing of venipuncture whole
blood, serum or plasma
Biohazard disposal container
Disposable gloves
Pipette and pipette tip
For fingerstick samples, the following materials are required:
Alcohol pad
Sterile lancet
Sterile gauze or cotton
Reagents and Materials Provided
1. Test cassette(individually pouched)
2. Each pouch contains one cassette with one desiccant bag
3. Diluent buffer
4. Instruction for use
5. Plastic dropper(optional)
Storage
COVID-19 IgG/IgM Rapid Test Cassette should be stored in dark place
at 2-30°C for 12 months from the date of manufacture. Keep the test
cassette in sealed pouch until use. Once you have taken the test
cassette out of the pouch, use it immediately. Do not use the test
beyond the indicated expiration date.
Warning
For in vitro diagnostic use ONLY
Read the package insert completely before use.It is very important that the correct procedure is followed. Fail to add the patient sample may lead to a false negative result (i.e.a missed positive).
![]() |