Sign In | Join Free | My webtextiles.com
webtextiles.com
Products
Search by Category
Home > Testing Equipment >

HS-3163P Portable single-phase energy meter Test Equipment,Max.60A internal Current & Voltage source,accuac 0.1% Class

Categories Portable Energy Meter Test Equipment
Brand Name: SHENGDI TECHNOLOGY
Model Number: HS-3163P
Certification: ISO9001
Place of Origin: CHINA
MOQ: 1 Piece
Price: USD$1~100000/SET
Supply Ability: 50 pieces/month
Delivery Time: 15 -20 work days.
Packaging Details: WOODEN CASE
Safty: IP50
Accuracy: 0.1% Class
Current: MAX.60A
Weight: 7 KG.
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    HS-3163P Portable single-phase energy meter Test Equipment,Max.60A internal Current & Voltage source,accuac 0.1% Class

    HS-3163P Portable single-phase test system is a high-performance calibrating instrument which is designed with international new digital technology. This test system consists of an integrated single-phase wide range voltage & current source and a single-phase electronic reference standard meter of accuracy class 0.05%. It is wide measuring range, 0.05% class high accuracy ,high tolerance to unwanted external influences and more utility functions.

    HS-3163P is mainly used on-site to test energy meter’s installation,running and analyze power system.

    Main technical features

    • Internal small single-phase current source which synchronized with on-site voltage;
    • Outputs 0-16A current, meets user’s multiple model, multi-load point check.
    • Can connect with current clamps, uses to on-site online calibration;
    • Adopted ARM 32-bits core embedded system, and with 7 inch TFT LCD TOUCHED SCREEN;
    • HMI design, full screen touched operation, can continue to calibrate automatically according to the scheme;
    • Can save test data for 1000 energy meters;
    • Can be used as a reference standard meter or single-phase calibration device;
    • Small size, low weight, low consumption, high accuracy and portable;
    • Support Bluetooth, and can be controlled by APP (on phone or PC);
    • With self-protection, sound and light alarm functions when current overload.

    Main measurement functions

    • Independent generation of single-phase current loading conditions for verification of meters using the incoming supply voltage or internal independent generation of single phase voltage.
    • Active,reactive and apparent energy measurement with integrated error calculator and pulse output;Or with 3D and adjustable scanning head (Optional).
    • Automatically test creeping error,starting-up error,basic error and standard deviation error etc.;
    • Support energy constants verification or dial testing;
    • Support daily timing error testing;
    • Support current harmonic influence value testing;
    • When calibration, user can choose testing points freely, also can make calibration scheme freely;
    • Testing data can be saved in instrument and inquiry, and allow data import& export;
    • Can display vector diagram, harmonic spectrum and wave form to analyze power system;
    • Measure voltage, current directly or by current clamps;
    • Measureactive,reactive power and apparent power;
    • Measure phase angle,PF and frequency;

    Application Range

    • Calibrate different types of energy meters before they are installed on-site;
    • Analyze energy meter running condition and error data;
    • Used for R&D and maintenance test;
    • Test and monitor power system.

    2,General Technical Index

    Auxiliary power supply198 VAC … 253 VAC / 47 … 63 Hz
    Power consumption200 VA
    ShellHard plastic
    Dimension355 x 272 x 166 mm(W*H*D)
    Weight≤7KGS( not including spare parts)
    Working Temp.-10 °C +50 °C
    Storage Temp.-20 °C … +60 °C
    R.H.≤85%,≤21°C

    3,Voltage source technical standard

    Output voltage range/power20 V … 300 V / 20 VA
    Resolution0.001 V
    THD≤ 0.5%
    Stability≤ 0.05% (3 min.)
    Adjust range0% … 120%(240V)
    Frequencyrangeaccuracyresolution
    45 Hz – 65 Hz±0.01 Hz0.01 Hz

    4,Current source technical standard

    Output current range/power5 mA … 60 A / 50 VA

    Current output(Terminal)

    currentrangeSmax / Umax
    0.1 A5 mA … 100 mA0.6 VA / 6 V
    1 A0.1 A … 1 A5 VA / 5 V
    10 A1 A … 10 A12 VA / 1.2 V
    50 A10 A … 50 A50 VA / 1 V
    Resolution0.01%*range
    THD≤ 1%
    Stability≤ 0.05% (3 min.)
    Adjust range0% … 120%
    Phase anglerangeaccuracyresolution
    0°…359.99°0.2°0.1°
    Frequency
    rangeaccuracyresolution
    45 Hz – 65 Hz±0.01 Hz0.01 Hz

    5,Reference standard meter technical standard

    5.1,Measurement range

    Measurementrangeinput/ sensor
    Voltage10 V … 300 VU
    Current5 mA … 60 AI
    10 mA … 120 Aclamp 20A,100A

    5.2,Voltage and current measurement accuracy

    voltage / current≤±E[%]1 2
    Measurementrangeclass
    Voltage100 V … 300 V

    10 V … 100 V

    0.05

    0.2

    Current20 mA … 60 A

    5 mA … 20 mA

    0.05

    0.2

    Clamp10% ≤ RG ≤ 120%

    1% ≤ RG < 10%

    0.2

    0.5


    5.3,Energy measurement accuracy

    Power/energy voltage:100 V … 300 V≤±E[%]1 2 3
    Measurement /output currentrangeclass
    Active power(P),apparent power(S)
    Output20 mA … 60 A

    5 mA … 20 mA

    0.05

    0.2

    Clamp10% ≤ RG ≤ 120%

    1% ≤ RG < 10%

    0.2

    1.0

    Reactive power(Q)
    Output20 mA … 60 A

    5 mA … 20 mA

    0.1

    0.2

    Clamp10% ≤ RG ≤ 120%

    1% ≤ RG < 10%

    0.4

    1.0

    Magnetic influence:≤0.07 % / 0.5 mT³(45 Hz … 66 Hz);

    Temp. coefficient(TC):
    range≤ ±TC[%/℃] 3
    0 … +40 0.02
    -10 … +50 0.05

    5.4,Frequency,phase,PF measurement accuracy

    F/Phase angle/PF≤ ±E
    Measurementrange
    F45 HZ … 65 Hz0.01 Hz
    θ0.00° … 359.99°0.1°
    PF-1.000 … +1.0000.002

    remarks:

    1. x.x: Related to measurement value

    x.x: Related to measurement range(Max range,FS),E(M)=FS/M*x.x( for example: 0.2, FS =46 v, E(10V) = 46/10 * 0.2 = 0.92 %)

    1. Basic frequency range: 45 … 65 Hz
    2. S:x.x,P,Q:x.x/ PF

    5.5,Pulse input/output

    Input TTL3 … 6 VDC
    Input FMax.200 kHz
    Output TTL5 VDC
    Pulse width≥ 10μs
    Constants:

    Active power,reactive,apparent power

    [imp/kWh(kvarh,kVAh)]

    C = 1×109/In’;In’= In×(100%,50%,25%)

    Constants depends on internal ranges(In)

    Details see constants table

    Current In[A]
    Measurement0.111050
    100%In50%In25%In
    Output FC’= C/3600000[imp/Ws(vars,Vas)]

    fo = C’×P∑(Q∑,S∑)

    fmax = 16.666kHz

    6,Others

    Position1
    COM. portRS232,Bluetooth
    Energy error indication range-99.999%~+2000.0%
    Other functionsVictor diagram display,error display,harmonic analysis display


    Buy HS-3163P Portable single-phase energy meter Test Equipment,Max.60A internal Current & Voltage source,accuac 0.1% Class at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Zhejiang Shengdi Technology Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0