Brand Name: Aolittel or Neutral
Model Number: CWFB0103FC-312XSP12
MOQ: 100 Pieces
Price: Negotiable
Payment Terms: T/T, Western Union,Paypal
Supply Ability: 1,000,000 Pieces Per Month
Delivery Time: 2-4 Weeks
Packaging Details: Bulk ,300pcs per carton ,16kg/carton
Type: Air Water Solar Micro Temperature Sensor 10K
Resistance at 25C: 10KΩ±1%
B25/85: 3977K±1%
B25/100: 3995±1%
Housing: Blue Plastic Housing
Coating: Thermally Conductive Epoxy
Cable: TPE AWG24(0.5mm*2C) OD3.3mm (Red and White)
Casing: Heat shrinkable casing (Ф7+Ф8)
Cable Length: 10 feet (customized)
Withstand voltage: 1500VAC 5sec
Operating temperature: -40~+105C
Response speed: 15 sec
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Air Water Solar Micro Temperature Sensor 10K With 10-Feet Cable Replacement Pool Spa Automation Control Systems and Pump


    Air Water Solar Micro Temperature Sensor 10K With 10-Feet Cable Replacement Pool Spa Automation Control Systems and Pump


    Description


    This air/water/solar temperature sensor is designed to use with Pentair IntelliTouch, EasyTouch, SunTouch, Compool pool and spa automatic control system and also compatible with Pentair MiniMax Plus pool and spa heater pump. Includes 10K-Ohm thermistor, 10-feet cable.


    ______________________________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________


    Dimension (mm)



    Material


    NOCOMPONENTMATERIAL AND SPECIFICATIONSQ'TYREMARK
    aELEMENTR25=10KΩ±1% B25/85=3977K±1% B25/100=3995±1%1 
    bHOUSINGPlastic Housing1Blue 
    cCOATINGThermally Conductive Epoxy 
    dLEAD WIRE

    TPE AWG24(0.5mm*2C) OD3.3mm

    (Red and White)

    (both ends stripped but not tinned)

    1Gray
    eCASINGHeat shrinkable casing (Ф7+Ф8)3Blue

    Performances


    NOItemSignTest ConditionsMin.Normal valueMax.Unit
    IResistance at 25℃R25

    Ta=25±0.05℃

    PT≦0.1mw

    9.90010.00010.100
    IIB ValueB25/853937.33977.04016.7k
    B25/1003955.0539954034.95
    IIIDissipation factorσTa=25±0.5℃2.5/mw/℃
    IVTime constantτTa=25±0.5℃//15sec
    VIInsulation resistance/500VDC100//
    VIIWithstand voltage/1500V AC5//Sec
    VIII.Operating temp.range//-40/+105

    Reliability Test


    NOItemTechnical requirementsTest conditions and method
    1.High temp. Test

    DR/R25£±3%


    DB/B£±3%


    No change with withstand voltage,

    Insalution performance.

    Appearance without damage.

    105±5℃,power on 500±24 hrs,DC0.2mA
    2.Low temp. tes-40±5℃,power on 500±24 hrs,DC0.2mA
    3.Endure moisture testStore in environment 55±2℃,90%-95%RH for 500±24 hrs
    4.Temp. cycle test–20℃×30min→Room temp.×10min→ in 100℃ water×30min→Room temp.×10min 10 cycles
    5Load electrify testPower on DC1mA,500hrs in room temp. and humid.
    6Tensile testsApplying 2 kg force lasts 1 min.
    7Drop testFree fall into concrete floor from height 1M ,10 cycle.
    8Vibration testFrequency range:10~55HZ Total amplitude 1.52mm 1 cycle 1 min ,direction and time X,Y,Z axs 2Hr each.
    9Bending testBend 180°binding site wire and epoxy resin.Back and forth 10 times

    Advantages


    Keep your pool a cool, comfortable temperature with the correct sensor! This aftermarket temperature sensor can be used as a water, air, or solar temp sensor for Pentair’s IntelliTouch, EasyTouch, and SunTouch swimming pool control systems.


    Micro Temeperature Sensor can be strapped to a pipe with a clamp to measure water temperature, or it can also be used to measure air temperature for use as Freeze protection. The temperature sensor is also used as a solar sensor, placed near solar panels, to detect temperatures near the panel, to determine when conditions are right to send water to solar panels. Micro Temeperature Sensor includes a 10 ft 2-wire cable to connect to internal home panels, or when solar panels are located far from the controller.


    Features


    • Water/Air/Solar - The AquaLink RS provides terminals for up to three Temperature Sensors, specifically for Water, Air, and Solar
    • 10K Ohms Thermistor
    • Compatible with Zodiac, Jandy, and Polaris Controls
    • Compatibility: Pentair’s IntelliTouch, EasyTouch, and SunTouch systems
    • Replaces: Pentair 520272, TS5T, and STS5T (red and black wires)
    • Includes 10K ohms NTC thermistor, 10-feet cord, 1 O-rings


    Function


    To use as a water temperature sensor: Insert the sensor into a small opening in the pipe between your pool's filter pump and filter using a hose clamp.

    To use as an air temperature sensor: Mount the sensor in open air outside the power center in the shade and away from air conditioners, motors, and other heat sources.

    To use as a solar temperature sensor: Fasten the sensor next to solar panels for unglazed panels or suspend between the collector and glazing for glazed panels.


    Resistance Vs. Temperature Chart


    R-T CONVERSION TABLE
    R25=10.00KΩ±1% B25/85=3977K±1%
    T/℃RminRcenRmaxT/℃RminRcenRmax
    -40352.8365337.2659322.3502-236.901036.070035.2541
    -39329.7864315.4439301.6950-135.032834.261433.5037
    -38308.3974295.1810282.5028033.270132.554231.8505
    -37288.5391276.3558264.6605131.606530.942130.2886
    -36270.0923258.8572248.0646230.035829.419228.8125
    -35252.9476242.5831232.6201328.552327.980227.4169
    -34237.0049227.4402218.2397427.150726.619926.0970
    -33222.1724213.3428204.8436525.826025.333724.8483
    -32208.3658200.2120192.3580624.573624.117023.6666
    -31195.5077187.9756180.7156723.389122.965822.5479
    -30183.5270176.5670169.8540822.268521.876121.4885
    -29172.3586165.9252159.7160921.208120.844420.4849
    -28161.9422155.9939150.24901020.204119.867219.5340
    -27152.2226146.7212141.40441119.253418.941418.6326
    -26143.1489138.0594133.13761218.352918.064017.7779
    -25134.6743129.9646125.40711317.499517.232216.9673
    -24126.7556122.3962118.17501416.690616.443416.1982
    -23119.3529115.3168111.40611515.923715.695115.4683
    -22112.4294108.6918105.06791615.196314.985114.7753
    -21105.9514102.489399.13041714.506214.311114.1173
    -2099.887496.679993.56601813.851213.671313.4923
    -1994.208691.236388.34891913.229513.063612.8984
    -1888.888186.133283.45532012.639112.486212.3340
    -1783.901381.347478.86342112.078411.937611.7973
    -1679.225276.857374.55272211.545511.416111.2870
    -1574.838672.642870.50432311.039210.920310.8015
    -1470.722068.685466.70082410.557810.448710.3396
    -1366.857164.968063.12592510.100010.00009.9000
    -1263.227161.474559.7645269.67309.57319.4732
    -1159.816458.190356.6027279.26649.16679.0671
    -1056.610455.101553.6274288.87918.77978.6806
    -953.595652.195350.8265298.51008.41128.3127
    -850.759749.460148.1889308.15838.06017.9623
    -748.090846.884645.7041317.82307.72567.6286
    -645.578344.458843.3624327.50337.40677.3107
    -543.212142.173041.1546337.19847.10277.0077
    -440.982940.018339.0725346.90746.81296.7189
    -338.881937.986537.1081356.62986.53636.4435

    R-T CONVERSION TABLE
    R25=10.00KΩ±1% B25/85=3977K±1%
    T/℃RminRcenRmaxT/℃RminRcenRmax
    366.36486.27256.1809741.57591.53131.4878
    376.11196.02075.9303751.52461.48091.4384
    385.87035.78045.6913761.47521.43251.3909
    395.63955.55095.4631771.42771.38591.3452
    405.41905.33175.2453781.38191.34101.3012
    415.20835.12235.0373791.33781.29781.2589
    425.00694.92234.8386801.29541.25621.2181
    434.81434.73114.6488811.25441.21611.1789
    444.63014.54834.4675821.21501.17751.1411
    454.45394.37354.2941831.17701.14031.1047
    464.28544.20644.1284841.14041.10451.0696
    474.12414.04653.9699851.10511.06991.0358
    483.96973.89353.8183861.07101.03671.0033
    493.82183.74703.6733871.03821.00450.9719
    503.68033.60693.5346881.00650.97360.9417
    513.54473.47263.4017890.97590.94370.9125
    523.41473.34413.2746900.94640.91490.8844
    533.29033.22103.1528910.91800.88710.8573
    543.17093.10303.0362920.89050.86030.8311
    553.05652.99002.9245930.86400.83450.8059
    562.94692.88162.8175940.83840.80950.7815
    572.84172.77772.7149950.81370.78540.7580
    582.74082.67812.6166960.78980.76210.7353
    592.64392.58262.5224970.76670.73960.7134
    602.55102.49092.4320980.74440.71790.6923
    612.46182.40302.3452990.72290.69690.6718
    622.37622.31852.26211000.70210.67670.6521
    632.29402.23752.18221010.68200.65710.6331
    642.21502.15972.10561020.66250.63820.6146
    652.13922.08502.03211030.64370.61990.5969
    662.06632.01331.96151040.62560.60220.5797
    671.99631.94441.89371050.60800.58510.5630
    681.92891.87821.82851060.59100.56860.5470
    691.86421.81451.76601070.57450.55260.5315
    701.80201.75331.70591080.55860.53710.5164
    711.74211.69451.64811090.54320.52220.5019
    721.68461.63801.59251100.52830.50770.4879
    731.62921.58361.5391

    10K Temperature Sensor Install Guide for IntelliTouch EasyTouch and SunTouch


    APPLICATION:


    Temperature Sensor used with the IntelliTouch®, EasyTouch® and SunTouch™ Systems. This sensor may be used as a Water, Air,or Solar sensor.


    REPLACEMENT KIT (P/N CWFB0103FC-312XSP12) INCLUDES:


    QTY. DESCRIPTION
    1 Temperature Sensor, 10K, 10 ft.
    1 O-Ring


    INSTALLATION:


    Water Temperature Sensor Replacement


    1. Find the old Water Sensor located between the filter pump and the filter. Remove old Sensor and position the hose clamp over the new Sensor, and gently tighten around pipe.
    Caution: Do not overtighten clamp.


    2. Feed the cable up through the low voltage compartment of the Load/Power Center to the Control Panel. Strip wires 1/4 in. and connect Sensor wires to WATER screw terminals.


    Solar Temperature Sensor


    1. For unglazed panels, fasten Sensor next to solar panels. For glazed panels, suspend Sensor between collector and glazing.
    2. Feed the cable up through the low voltage compartment of the Load/Power Center to the Control Panel. Strip wires 1/4 in. and connect Sensor wires to the SOLAR screw terminals.


    Ambient Air Temperature (Freeze Protection) Sensor


    1. Mount sensor in open air, in shaded area, away from air conditioners. Feed the cable up through the low voltage compartment of the Load/Power Center to the Control Panel, fastening to plumbing with cable ties. Strip wires 1/4 in. and connect Sensor wires to AIR screw terminals.


    For more information click on the images below:


    Sensor Installation
    Image 1Image 2
    jandy water air solar temperature sensor installation
    Troubleshooting Flow Chart For Water Temperature Sensor
    Image 1Image 2
    Troubleshooting Flow Chart For Water Temperature SensorTroubleshooting Flow Chart For Water Temperature Sensor
    Buy Air Water Solar Micro Temperature Sensor 10K With 10-Feet Cable Replacement Pool Spa Automation Control Systems and Pump at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Aolittel Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0