Input Voltage: -48VDC
Output Voltage: +28VDC
Output Power: 400W
Output efficiency: natural cooling
Output Efficiency: 87%
Temperature Coefficient: ±0.03 % / °C
Product Name: Industrial Power Supplies
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    48V DC Input Voltage Industrial Power Supplies 400W Output Power GPDD401M28-1A


    48V DC Input Voltage Industrial Power Supplies 400W Output Power GPDD401M28-1A


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)Input Voltage: -48VDC
    Brand Name: ESTELOutput Voltage: +28VDC
    Model Number: GPDD401M28-1AOutput Power: 400W
    Product Name: Industrial Power SuppliesOutput Efficiency: 87%
    Certification: ISO9001, CE, 3C, FCC, TLCMax. Output Current: 15A
    Application: Industrial EquipmentTemperature Coefficient: ±0.03 % / °C

    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, T/T, D/A, D/P, Western Union
    Supply Ability:20,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton/wooden case

    1. Description


    The GPDD401M28-1A industrial power supply support wide input voltage range (-40VDC to -56VDC), with single way output. The power supply includes the following functions: input over/under voltage protection, output short-circuit protection, over current protection etc. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.


    2. Technical Parameters


    Ambient conditions
    ParametersMinTypicalMaxUnitNote
    Operating temperature-402570°C
    Storage temperature-402570°C
    Relative humidity95%non-condensing
    Altitude3000m
    Atmospheric pressure70106KPa
    CoolingNatural cooling

    Input
    ParameterMinTypicalMaxUnitNote
    Input voltage range-40-48-57Vac

    Basic output characteristics
    ParameterMinTypicalMaxUnitNote
    Output voltage range+28V28VdcAdjustable
    Output current range+28V015A
    Load regulation±1.5%
    Voltage regulation accuracy±1%
    Line regulation±0.5%
    Ripple (peak to peak value)+28V1% Nominal output voltage value%At rated input/output, with one 0.1uF ceramic capacitor and one 10uF electrolyte capacitor condition, bandwidth is 20MHz.
    Output power400W
    Output efficiency87%Rated input and load
    Temperature coefficient±0.03%/°CAt 20 °C environment temperature
    Load effect recovery time200uSLoad mutation, overshoot ≤ ±5% rated output voltage
    Turn on/off overshoot±5%

    Protection
    ParameterMinTypicalMaxUnitNote
    Input over-voltage protection-65-72VdcSelf-recovery
    Input under-voltage protection-36VdcSelf-recovery
    +28V output over-voltage protection point31V
    +28V output current-limiting protection point15.7521.75AConstant current and cut-off protection way, automatic recovery, can use the hiccups
    Short-circuit protectionLong-time short-circuit,self-recovery
    Over-temperature protection°CYes

    EMC and others
    ParameterStandard and requirements
    CEEN55022 - Class B
    REEN55022 - Class B
    SurgeEN61000-4-5 LEVEL 3, line-line 2KV, line-earth 4 KV
    ESDEN61000-4-2 contact discharge: ±6KV, air discharge: ±8KV. (criterion B)
    RSEN61000-4-3 test frequency: 27MHz~800MHz, 800MHz~ 960MHz, 960MHz~1400MHz, 1.4GHz~2GHz; electric field intensity: 3V/m; 10V/m; 3V/m; 10V/m; Amplitude modulation: 80%AM(1kHz)
    CSEN61000-4-6 test frequency: 0.15 MHz~ 80 MHz, test strength: 3V, amplitude modulation: 80%AM(1kHz)
    EFT/BEN61000-4-4
    Voltage dips and short interruptionsEN61000-4-11 fall to 30%Ut, duration 10ms; fall to 60%Ut, duration 500ms; fall to 95%Ut, duration 5000ms; criterion B, criterion C
    VibrationFrequency 10 Hz~55 Hz(Sine scanning), amplitude 0.35 mm
    ShockPeak acceleration 150 m/s2, duration 11 ms
    Collision testCollision waveform: half sine wave; peak acceleration: 180m/s2; pulse width: 6ms; collision direction: 6 direction; collision times: 100 times at each direction.
    Static pressure test

    TL=Wt×(S-1)×F×9.8(N)

    TL: pressure value, unit: N; Wt: package weight, unit: kg; S: allowed stacking layer, select the largest stacking layer; F: safety coefficient, usually choose 5; time to put pressure: 2 h

    Moisture proofGB/T2423.4-1993 alternating damp heat test, 24~ 45°C, 95%RH,48h
    Mold proofGB/T2423.16-1999 mold test , grade 2
    CoolingModule natural conduction cooling
    Noise55dB(A); test distance 1m
    MTBFMTBF≥200,000h
    Annual return rate≤1%
    Smelling requirementsNo peculiar and harmful smell

    Safety and insulation grade
    ParameterRequirementNote
    Input –output1000Vac/10mA//1minNo flashover, no breakdown, remove discharge tube when testing
    Input –earth1000Vac/10mA//1min
    Output –earth500Vdc/10mA//1min
    Grounding resistance<0.1Ω
    Insulation resistance≥10MΩIn normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulation resistance of input-output, input-grounding, output-grounding are all ≥10MΩ
    Leakage current≤3.5mA
    Grounding resistance<0.1Ω

    Mechanical Features
    L×W×H (mm)230×61×47.5mm
    Weight(kg)≤1Kg


    3. Alarm



    ItemYes/NoTechnical indexNote
    Power failure alarm signal

    Yes


    Input: normal, output: low impedance;

    Input: failure, output: high impedance;


    When DC input fails, alarm signal of +28V output at full load rise to +2.2V, (need to add pull-up resistor when test). Time interval for +28 V falling to +15V shall not be less than 1 ms.
    Input normal LED display

    Yes

    Use indicator light (red): red light turn on means input is normal
    Output normal LED display

    Yes

    Use indicator light (green): green light turn on means output 28V is normal

    4. Packing and Shipping




    5. Our Delivery Agent


    The goods can be shipped by sea, by air, by courier, by land, by train, etc. Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


    6. Our Contact Information


    Mobile Phone: 0086-13752765943

    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Buy 48V DC Input Voltage Industrial Power Supplies 400W Output Power GPDD401M28-1A at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0